Tuesday, September 15, 2009

Music is the engine of new U-M lab-on-a-chip device VIDEO

ANN ARBOR, Mich.---Music, rather than electromechanical valves, can drive experimental samples through a lab-on-a-chip in a new system developed at the University of Michigan. This development could significantly simplify the process of conducting experiments in microfluidic devices.

A paper on the research was published online in the Proceedings of the National Academy of Sciences the week of July 20.

A lab-on-a-chip, or microfluidic device, integrates multiple laboratory functions onto one chip just millimeters or centimeters in size. The devices allow researchers to experiment on tiny sample sizes, and also to simultaneously perform multiple experiments on the same material. There is hope that they could lead to instant home tests for illnesses, food contaminants and toxic gases, among other advances.

Mark A. Burns, P.E.

Mark A. Burns, P.E. 3074F Dow (734) 764-1516, FAX: (734) 763-0459 maburns@umich.edu, Biochemical separations, field-enhanced separations, microfabricated chemical analysis systems, DNA genotyping and sequencing.
To do an experiment in a microfluidic device today, researchers often use dozens of air hoses, valves and electrical connections between the chip and a computer to move, mix and split pin-prick drops of fluid in the device's microscopic channels and divots.

"You quickly lose the advantage of a small microfluidic system," said Mark Burns, professor and chair of the Department of Chemical Engineering and a professor in the Department of Biomedical Engineering.

"You'd really like to see something the size of an iPhone that you could sneeze onto and it would tell you if you have the flu. What hasn't been developed for such a small system is the pneumatics---the mechanisms for moving chemicals and samples around on the device."

The U-M researchers use sound waves to drive a unique pneumatic system that does not require electromechanical valves.
Instead, musical notes produce the air pressure to control droplets in the device. The U-M system requires only one "off-chip" connection.

"This system is a lot like fiberoptics, or cable television. Nobody's dragging 200 separate wires all over your house to power all those channels," Burns said. "There's one cable signal that gets decoded."
The system developed by Burns, chemical engineering doctoral student Sean Langelier, and their collaborators replaces these air hoses, valves and electrical connections with what are called resonance cavities. The resonance cavities are tubes of specific lengths that amplify particular musical notes.

These cavities are connected on one end to channels in the microfluidic device, and on the other end to a speaker, which is connected to a computer. The computer generates the notes, or chords. The resonance cavities amplify those notes and the sound waves push air through a hole in the resonance cavity to their assigned channel. The air then nudges the droplets in the microfluidic device along.


Fight song moves droplets, This video provided by College of Engineering researchers uses the Michigan fight song to demonstrate how sound waves can be used to move droplets through microfluidic devices.
"Each resonance cavity on the device is designed to amplify a specific tone and turn it into a useful pressure," Langelier said. "If I play one note, one droplet moves. If I play a three-note chord, three move, and so on. And because the cavities don't communicate with each other, I can vary the strength of the individual notes within the chords to move a given drop faster or slower."

Burns describes the set-up as the reverse of a bell choir. Rather than ringing a bell to create sound waves in the air, which are heard as music, this system uses music to create sound waves in the device, which in turn, move the experimental droplets.

"I think this is a very clever system," Burns said. "It's a way to make the connections between the microfluidic world and the real world much simpler."

The new system is still external to the chip, but the researchers are working to make it smaller and incorporate it on a microfluidic device. That would be a step closer to a smartphone-sized home flu test. ###

The paper is called, "Acoustically-driven programmable liquid motion using resonance cavities." Other authors are U-M chemical engineering graduate students Dustin Chang and Ramsey Zeitoun. The research is funded by the National Institutes of Health and the National Science Foundation. The University is pursuing patent protection for the intellectual property, and is seeking commercialization partners.

For more information:

Mark Burns: www.engin.umich.edu/dept/cheme/people/burns
Sean Langelier: www.engin.umich.edu/dept/che/research/burns/Sean

Michigan Engineering:

The University of Michigan College of Engineering is ranked among the top engineering schools in the country. At more than $130 million annually, its engineering research budget is one of largest of any public university. Michigan Engineering is home to 11 academic departments and a National Science Foundation Engineering Research Center. The college plays a leading role in the Michigan Memorial Phoenix Energy Institute and hosts the world class Lurie Nanofabrication Facility. Find out more at www.engin.umich.edu/.

Contact: Nicole Casal Moore ncmoore@umich.edu 734-647-1838 University of Michigan

No comments: